1. Temperature dimming control:
    adjust heating efficiency according
    to environmental temperature;
2. Different temperature control
    alternative for daytime and
    nighttime mode;
3. Timing control: two timing output
    alternations of ON and OFF for
    every 24 hours;
4. Sound alarms when exceeding
    temperature limit and mute sound
    manually;
5. Temperature dial calibrated in Fahrenheit and Centigrade.
 
Menu instructions:  

Menu item

Set

Default value

Remark

         HEAT(MODE)

HEAT

HEAT

 

Daytime Temperature
(SET)

0.0~50.0°C

25°C

Set step 0.1°C

Nighttime Temperature(SET)

0.0~50.0°C

20°C

 

Daytime FROM   

00:00—22:59

08:00

 

Daytime TO

01:00—23:59

18:00

If TO time is earlier than

FROM time, display

error message "ERR".

Alarm over temperature

0.0~5.0°C

5.0°C

Set step 0.1°C

First Timing control L1:

ON: FROM, OFF: TO

00:00~23:59

00:00~06:00

Disabled if FROM and

TO are same

Second Timing control L2:

ON: FROM, OFF: TO

00:00~23:59

12:00~18:00

Disabled if FROM and

TO are same

Real Timer

00:00~23:59

Real-time

 

 


back.gif